Retour à Solutions

Chambre hôtelière standard

Référence d'ingénierie — topologie réseau, câblage par chambre et nomenclature.

Panneaux interrupteurs pour hôtels — éclairage, touches scène, card power et RCU dans un BOM chambre standard. Panneaux toucher chambre (verre et LCD) aveccatalogueetpanneaux tactiles.

  • 36RCU host models
    Wired / wireless / bus
  • 91+Smart switch panels
    Scenes / dimming / environmental
  • 11Product categories
    Card power · door locks · modules, etc.
  • 4 routesDeployment routes
    Central wired · wireless · RS485· hybrid
Hotel guestroom RCU and smart panel hardware solution reference

For different hotel types

Une plateforme matérielle unique — les combinaisons de modèles recommandées et les méthodes d’installation varient selon l’échelle de l’établissement.

Boutique B et amp;B guestroom hardware scenario

Boutique hotels& B et amp;B· light retrofit

Wireless or RS485 retrofit with minimal wall chase and fast delivery; per-room hardware includes card power, panels and basic modules.

  • Card power + door contact + multi-key scene panel kit
  • Wireless or bus models selected by site conditions
  • Per-room wiring diagrams provided for on-site electrician installation
View serviced apartment solution →

Guestroom control tech · four deployment routes

Select RCU and panel models by site conditions — this page is aselection referenceonly; per-room wiring diagrams, terminal tables and BOMs are on each route'stechnical solution detail page(guestroom control tech solution index).

Wireless RCU smart guestroom control

Wireless panels and card power with minimal chase and short schedule; suited to legacy building retrofit and quick-turn B et amp;B properties.

Retrofit · partial renovation

Wireless solution details · wiring& BOM →

Wired smart guestroom control system

LV enclosure RCU + star panel wiring; card power, door sign and multi-circuit modules — stable and reliable.

New build · upscale preferred

Wired solution details · wiring& BOM →

RS485 bus guestroom control

Modules and panels share unified bus addresses; chain standard-room template replication with open protocols for third-party host systems.

Chain · standard room

RS485 solution details · address table →

Standard room per-room hardware BOM · 6-point template

Industry-standardper-room point listfor upscale and chain projects — wired RCU and wireless retrofit share thesame hardware categories; differences are in bus, gateway and module models. The table below can be cited in bid documents and point diagrams; software platform is implemented by the integrator.

#Per-room pointKey functionsPoint Pur Intelligent subsystem
1Door contact · doorbellDND / MUR / doorbell dry contact; door contact linked to card powerDoor sign& card power
2Entry triple panelCard power, housekeeping/DND, corridor / bath / exhaust / master controlCard power
3ThermostatFCU / VRF; Welcome / away temperature presetEnvironmental control
4Left · right bedsideOutlets + USB;curtain / sheer open ·close; bright / sleep / readingMotorized curtains·Scene panels
5Desk triple panelDesk lamp, duplex outlet, USB chargingInfo panels
6RCU hostLocal scenes; offline keep-alive; open protocol for integratorsRCU catalog

* List structure follows industry guestroom control conventions; specific circuit counts, panel key layouts and motor channels per contract BOM version. Curtain solution:Motorized curtains · scene linkage table.

Panel scene configuration reference

The following describespanel scenes achievable in hardware— Welcome, night path, privacy and other preset logic configured in RCU/panels, not hotel operations software features.

Guestroom scheduled curtain opening for natural light

Harness natural light · morning wake-up

Motorized curtains/blinds can open on schedule or via panel scenes; paired with Welcome scene to replace harsh lighting for wake-up.

  • Scheduled morning curtain open — sheer first to preserve privacy layer
  • Curtain and HVAC coordination: summer shading reduces load, winter light adds warmth
  • Panel / App one-touch "full open / half open / blackout"
Motorized curtain solution →

Typical solution scenarios

Alternating image and text showcasing typical per-room hardware nodes and public-area module reuse.

Smart guestroom Welcome mode scene

Per-room · card power& scene panels

Card/keyless power, multi-key scene panels and RCU relay linkage — engineering acceptance per circuit table and wiring diagram item by item.

  • Card power + door contact: no power when unoccupied
  • Reading, sleep, night path and other scenes preset in panel/RCU
  • Motorized curtains coordinated with lighting and HVAC module wiring
Card power solution →
Contactless self check-in scenario

Door sign · card power · door lock nodes

Door sign panel, card power and door lock dry contacts connected to RCU — PMS/guestroom control software linkage implemented by integrator at protocol layer.

  • DND / MUR door sign hardware and in-room scene keys
  • Card power circuit and door lock signal terminal definitions
  • Open API and RS485 register documentation in developer docs
Door sign& card power →
Hotel lobby and public-area smart control scenario

Public areas · first impression& on-demand energy saving

Reception zone precision lighting and HVAC; corridor occupancy lighting; banquet/meeting mode one-touch switching — public-area energy can account for a significant share of total property consumption. Per-floor/per-zone lighting schedules + temperature/humidity sensors and weather data linked to HVAC, avoiding idle operation in lobby, restaurant and meeting floors.

  • Lobby, reception: lasting first impression with auto brightness switching for operating/non-operating hours
  • Meeting rooms: meeting / projection / break scenes with delayed shutoff when unoccupied
  • Corridors& stairs: occupancy-based lighting, dim or off when unoccupied
  • Per-floor lighting schedules + dynamic temperature control supporting green hotel sub-metering
Public area back-of-house solution →·Energy saving topic →
RCU enclosure and modular expansion

Modular RCU · circuit expansion

Enclosure + hot-swap relay/dimming/HVAC modules configured by per-room circuit count; modular spares simplify engineering after-sales.

  • Same series covers economy to upscale circuit counts
  • Terminal table + BOM template available from engineers
  • Intégration protocole viaAPI développeur(SaaS cloud non requis)
RCU model catalog →

Wiring method comparison

Group upscale properties favor centralized bus for reliability; chain new builds can use "wired primary, wireless auxiliary"; legacy small properties can choose pure wireless.

Comparison itemCentral wired RCURS485 busWired + wirelessPure wireless
Use caseUpscale new buildSmall/mid chainChain retrofitBoutique B et amp;B
Stability★★★★★★★★★☆★★★★☆★★★☆☆
Installation flexibility★★☆☆☆★★★☆☆★★★★☆★★★★★
Retrofit costHigherMediumMediumLower
Response speed★★★★★★★★★☆★★★★☆★★★☆☆

Hardware topology overview

Integrator host or third-party guestroom control platform (optional) → RCU/gateway → guestroom terminal hardware; Point Pur Intelligent primarily delivers thelower two hardware layers.

RCU and guestroom hardware topology overview
Point Pur Intelligent guestroom hardware · logical layers
Integrator guestroom control / PMS gateway (optional)Developer APIModbus / RS485 custom
RCU smart host / gatewayLocal scenes · offline keep-alive
Relay / dimming / HVAC modulesRS485· dry contact · bus expansion
Card power · door locks · panelsCurtains · sensors · door sign
Lobby · meeting · corridorBack-of-house · pool · outdoor lighting

Intégration protocole tiers (optionnel)

Point Pur Intelligent delivers hardware and protocol documentation; PMS, BMS and group platforms are integrated by the integrator — not Point Pur Intelligent core products.

RS485 / Modbus

Register tables and gateway protocol documentation for self-developed or third-party guestroom control hosts.

Dry contact& door sign

DND, MUR, SOS hardware nodes; status reporting logic implemented by host system.

Developer API

Developer APIand script examples supporting secondary integration.

PMS integration

Common industry PMS integration implemented by project integrator; Point Pur Intelligent can provide field mapping consultation.Protocol documentation →

Engineering solution reference (7 items)

Browse industry solutions by property type — this page is thestandard room master solution; chain, luxury, retrofit and more in the table below.

→ Engineering solution index

Guestroom capability solutions (9 items)

→ Guestroom capability solution index·→ Full product catalog

Project collaboration flow

Requirements discussion → solution drawings → RCU production → on-site commissioning → delivery training (manufacturer focuses on steps ③④ hardware and documentation).

① Requirements discussionRoom count, new build/retrofit, protocol and LV infrastructure status
② Solution drawingsPoint diagram, per-room wiring diagram, sélection panneaux et devis BOM
③ RCU productionHost programming, module procurement, factory commissioning
④ On-site commissioningInstallation supervision, module addressing, scene acceptance (intégration protocole pilotée par l’intégrateur)
⑤ Delivery trainingWiring manual, electrician/integrator training, spares and ticket support