Welcome sleep dimming switch
Hotel smart switch panels for guestroom lighting, scene keys and glass touch on RS485 — OEM/ODM Guangzhou since 1996.
Welcome sleep dimming switch
Welcome sleep dimming switch — Welcome and sleep dimming curves linked to RCU scene control. Welcome and sleep dimming curves for downlights and strips; common RS485 dimmer panel line item in hotel BOM.
- Welcome and sleep dimming
- Downlight and strip zones
- RS485 dimmer panel
- RCU curve presets
- Type
- Smart light switch
- Installation
- 86 mm back box · standard wall
- Panel
- Tempered glass touch · backlight indication
- Communication
- RS485 bus · network with RCU/modules
- Circuits
- single-circuit dimming output
- Dimming
- Long-press fade · short-press switch
- Load
- LED / halogen · select per project
- Delivery
- multi-finish optional · bulk project supply
Specifications
| Parameter | Specification |
|---|---|
| Product name | Smart light switch |
| Installation | 86 mm back box · standard wall |
| Panel material | Tempered glass touch · metal/glass multi-finish |
| control function | Smart light switch — Welcome and sleep dimming curves linked to RCU scene control. Tempered glass touch, RS485 bus, pairs with hotel RCU host. |
| Dimming method | RS485 bus commands · works with RCU dimmer module or 0–10V output |
| Communication method | RS485 bus · network with RCU/modules |
| Status indication | backlight indication · switch/dimming statusvisible |
| suitable forload | LED dimmable luminaires / halogen · confirm dimming curve during detailed design |
| Product series | lighting panel series · 1G–8G / dimming |
| Delivery | Bulk project supply · finish and load type per BOM notes |
Wiring diagram
Dimmer panel category wiring reference — dimming circuits must match RCU dimmer module or 0–10V/SCR output; terminal numbers and wire gauge per signed wiring atlas.
Installation notes
- Confirm load type (LED/halogen) and dimmer module model for dimming circuits during detailed design
- Configure dimming curve, minimum brightness and scene linkage logic in RCU program
- Lighting panel circuit schedule must be planned with RCU addresses during detailed design
- Wire per project drawing; signed projects use factory shipment drawings
- Commission with RCU after power-on: short-press switch, long-press fade, scene dimming — item-by-item acceptance
Downloads
Full specification, dimming curve notes, wiring drawings and certification — search the download center or contact sales for project BOM.
