Wireless RCU smart guestroom control
Wireless panels and card power with minimal chase and short schedule; suited to legacy building retrofit and quick-turn B&B properties.
Retrofit · partial renovationGuest room smart switch panel for hotels — standard BOM, wiring routes, 6-point template and links to RCU hosts, hotel smart switch panels and card power.
Smart switch panels for hotels — per-room lighting, scene keys, card power and RCU host in a standard guestroom BOM. Touch smart switch panels for hotel rooms (glass and LCD scene keys) pair with oursmart switch catalogandtouch panels.

One hardware platform — recommended model combinations and installation methods vary by property scale.

Wireless or RS485 retrofit with minimal wall chase and fast delivery; per-room hardware includes card power, panels and basic modules.

Fixed per-property hardware list and panel styles — new openings reuse the same models, reducing selection disputes and lead times.

Metal/glass touch panels can enter interior design material schedules; RCU expands by circuit count for multi-zone suite control.
Select RCU and panel models by site conditions — this page is aselection referenceonly; per-room wiring diagrams, terminal tables and BOMs are on each route'stechnical solution detail page(guestroom control tech solution index).
Wireless panels and card power with minimal chase and short schedule; suited to legacy building retrofit and quick-turn B&B properties.
Retrofit · partial renovationLV enclosure RCU + star panel wiring; card power, door sign and multi-circuit modules — stable and reliable.
New build · upscale preferredModules and panels share unified bus addresses; chain standard-room template replication with open protocols for third-party host systems.
Chain · standard roomRelay/dimming/HVAC modules mixed in slots; multi-zone suites with hot-swap spare replacement.
Upscale · suite expansionIndustry-standardper-room point listfor upscale and chain projects — wired RCU and wireless retrofit share thesame hardware categories; differences are in bus, gateway and module models. The table below can be cited in bid documents and point diagrams; software platform is implemented by the integrator.
| # | Per-room point | Key functions | PurePoint Smart subsystem |
|---|---|---|---|
| 1 | Door contact · doorbell | DND / MUR / doorbell dry contact; door contact linked to card power | Door sign& card power |
| 2 | Entry triple panel | Card power, housekeeping/DND, corridor / bath / exhaust / master control | Card power |
| 3 | Thermostat | FCU / VRF; Welcome / away temperature preset | Environmental control |
| 4 | Left · right bedside | Outlets + USB;curtain / sheer open ·close; bright / sleep / reading | Motorized curtains·Scene panels |
| 5 | Desk triple panel | Desk lamp, duplex outlet, USB charging | Info panels |
| 6 | RCU host | Local scenes; offline keep-alive; open protocol for integrators | RCU catalog |
* List structure follows industry guestroom control conventions; specific circuit counts, panel key layouts and motor channels per contract BOM version. Curtain solution:Motorized curtains · scene linkage table.
The following describespanel scenes achievable in hardware— Welcome, night path, privacy and other preset logic configured in RCU/panels, not hotel operations software features.

Motorized curtains/blinds can open on schedule or via panel scenes; paired with Welcome scene to replace harsh lighting for wake-up.

Avoid full bathroom ceiling lights at night — RCU preset "night path mode": corridor and bath lights ramp up at low level, auto-restore sleep scene on return to bed.

Guests adjust motorized blind angles or sheer/blackout combinations on demand; door sign syncs in DND state to reduce disturbance — upscale projects can reference luxury privacy mode.

Door contact, SOS, door lock low-battery and other events reported via RCU dry contacts or RS485 — received and processed by integrator software; PurePoint Smart provides sensor and door sign hardware.
Alternating image and text showcasing typical per-room hardware nodes and public-area module reuse.

Card/keyless power, multi-key scene panels and RCU relay linkage — engineering acceptance per circuit table and wiring diagram item by item.

Door sign panel, card power and door lock dry contacts connected to RCU — PMS/guestroom control software linkage implemented by integrator at protocol layer.

Reception zone precision lighting and HVAC; corridor occupancy lighting; banquet/meeting mode one-touch switching — public-area energy can account for a significant share of total property consumption. Per-floor/per-zone lighting schedules + temperature/humidity sensors and weather data linked to HVAC, avoiding idle operation in lobby, restaurant and meeting floors.

Enclosure + hot-swap relay/dimming/HVAC modules configured by per-room circuit count; modular spares simplify engineering after-sales.
Group upscale properties favor centralized bus for reliability; chain new builds can use "wired primary, wireless auxiliary"; legacy small properties can choose pure wireless.
| Comparison item | Central wired RCU | RS485 bus | Wired + wireless | Pure wireless |
|---|---|---|---|---|
| Use case | Upscale new build | Small/mid chain | Chain retrofit | Boutique B&B |
| Stability | ★★★★★ | ★★★★☆ | ★★★★☆ | ★★★☆☆ |
| Installation flexibility | ★★☆☆☆ | ★★★☆☆ | ★★★★☆ | ★★★★★ |
| Retrofit cost | Higher | Medium | Medium | Lower |
| Response speed | ★★★★★ | ★★★★☆ | ★★★★☆ | ★★★☆☆ |
Integrator host or third-party guestroom control platform (optional) → RCU/gateway → guestroom terminal hardware; PurePoint Smart primarily delivers thelower two hardware layers.

PurePoint Smart delivers hardware and protocol documentation; PMS, BMS and group platforms are integrated by the integrator — not PurePoint Smart core products.
Register tables and gateway protocol documentation for self-developed or third-party guestroom control hosts.
DND, MUR, SOS hardware nodes; status reporting logic implemented by host system.
Developer APIand script examples supporting secondary integration.
Common industry PMS integration implemented by project integrator; PurePoint Smart can provide field mapping consultation.Protocol documentation →
Browse industry solutions by property type — this page is thestandard room master solution; chain, luxury, retrofit and more in the table below.
→ Guestroom capability solution index·→ Full product catalog
Requirements discussion → solution drawings → RCU production → on-site commissioning → delivery training (manufacturer focuses on steps ③④ hardware and documentation).
Engineering topics · tender summary