Light retrofit
Wireless MESH / Zigbee or local RS485—minimal demolition, days per room, existing stock can roll out in batches.
Long-stay control, credential and energy policies for apartment operators.
Engineering Reference · Retrofit
Serviced-apartment projects often add guest controlafter fit-out. PurePoint Smart offers wireless / light RS485 / hybrid hardware routes by wall-break level; full wiring comparison inStandard Guestroom Control · Engineering Reference. Remote room control and similar software are implemented by integrators or third-party platforms; PurePoint Smart supplies devices and wiring documentation.
* Per-room timeline is typical wireless retrofit range; same layout should clone BOM and wiring diagram versions—do not re-spec per unit.
Serviced apartments need not use full hotel six-point BOM—the table is theminimum set for ~80% of engineering asks, expandable against the standard guestroom master.
| Node | Function | Recommended category | Capability / tech page |
|---|---|---|---|
| Door lock | Code / Bluetooth · checkout permission revoke | Smart locks | Access control |
| Card power | Card / cardless · vacant cutoff | Card slot power | Card power logic |
| Scenes | Welcome / sleep · bedside keys | Wireless/bus panels | Scene lighting |
| Gateway | Local scenes · optional API | Wireless RCU / gateway | Wireless tech page |
| Sensors | Door contact · occupancy (optional) | Smart sensors | Energy saving |
Pick the path before SKUs—engineering schedules and timeline comparison in column A tech solutions.
Serviced-apartment simplification aligned with hotel master wiring comparison—choose path, then BOM.
Minimal wall changes, timeline in days; suited to short-stay high turnover and finished units. Core: gateway + wireless switches + lock + card power.
Engineering focus:minimal chase · low per-room BOM · same layout wiring clone
Local low-voltage closet + panel bus, more stable than all-wireless; suited to long-stay apartments, larger units.
Engineering focus:unified bus addresses · consistent module spare codes
Public wired + guest wireless, or card power/lock wired + lighting wireless; suited to multi-layout properties.
Engineering focus:phased stocking · later module expansion for circuits
Wireless MESH / Zigbee or local RS485—minimal demolition, days per room, existing stock can roll out in batches.
Per-room wiring diagram + BOM template—electricians build to drawing; same layout clones SKUs, not redesign.
BOM by room type—card power + lock + panel core trio, hardware cost estimable.
Engineering rhythm from selection to acceptance—software integration optional fifth step by integrator.
Pick wireless/bus route and card power, panel, lock SKUs by layout
Gateway/card power/door contact/panels per per-room diagram
Module addresses, scene keys—local run acceptance
Same layout clones BOM and config—bulk stocking and delivery
Serviced-apartment pain point: "fit-out done, no more chasing." Light routes keep existing walls and furniture.
Same hardware base, different default BOM by segment—pick template at delivery to reduce per-unit disputes.

Code lock + card power + basic scene panel, delayed power-off after checkout—suited to OTA high turnover.
Card slot power →
RS485 or wireless bus, door contact + low-standby modules—protocol integration by integrator.
Energy saving →
Multi-key scene panel + dimming module + relay, optional RGB strip.
Environmental control →Serviced apartments need not use full catalog—the combo below covers ~80% of engineering asks; rest in cap-b and product pages.