Wired guestroom control

Star wiring to the RCU host per room — wiring tables for new-build and high-spec projects.

  • 6 points Standard room single-room BOM
    industry-aligned
  • Star Low-voltage topology
    per-room isolated · easy fault find
  • <100ms Scene switch response
    local RCU execution
  • 36+ RCU host models
    expandable circuits

* Wire gauge, cores, and terminal IDs per signed wiring atlas; table is PurePoint Smart engineering summary for tender docs and point diagrams.

Wired RCU single-room star low-voltage topology

Wired guestroom control · Four engineering essentials

Unlike wireless retrofit — wired fixes topology inconstruction phase, stability and maintainability inoperations.

Star low-voltage · per-room isolated

Panels, card power, door sensors, thermostats home-run to one RCU; no cross-room chaining; faults isolated per room for electrician and contractor troubleshooting.

Central relays · local scenes

Multi-circuit lighting, curtains, card power driven by RCU relays/dimmers; Welcome, sleep, night paths preset on host, no cloud dependency.

panels · reusable key maps

Bedside, entry, desk use standard 86 boxes; key/scene table in factory config; chain stores clone silk and logic.

Luxury new build · full fit-out first choice

Join at LV riser and conduit stage; one-time wiring long-term use; suited to international luxury and reliability-first projects.

Construction schedule comparison

Switch by property type — for tender "technology route" and closure plan; compare withwireless solution.

ComparisonWired guestroom control systemWireless RCURS485 bus
ScheduleFull fit-out low-voltage 15–25 days/floorInterleaved with fit-out, 5–10 days/floor12–18 days/floor
CablingStar low-voltage to each panelGateway power + wireless panelsSingle bus + module addresses
Best forFull-fit luxury, stability priorityTight-schedule new build / boutique chainChain standard room batch replication
RiskChase cost and scheduleWall shielding needs surveyAddress conflicts and terminal matching

Standard room BOM · Wired model mapping

Aligned withhotel parent 6-point template; typical PurePoint Smart subsystems for star wired deployment.

#Single-room pointWired engineering notePurePoint Smart subsystem
1Door sensor · doorbellRVV 2×0.75 to RCU DI; DND/MUR dry contactsDoor sign solution
2Entry triple panelCard power + scene keys; RELAY + DI to RCUCard power solution
3ThermostatRS485 shielded pair or HVAC module dry contactsHVAC solution
4Bedside panelRVV 6×0.75 to PANEL-BUS; sceneLighting solution
5Desk info panelRVV 4×0.75; always-on outlet independentInfo panels
6RCU smart hostWired RCU host+ relay / dimmer modulesRCU catalog

Wired RCU vs wireless RCU

Select by property — wired emphasizesstability and circuit expansion, wirelessretrofit schedule; same 6-point BOM types, different networking and modules.

ComparisonWired guestroom control systemWireless RCU guestroom control
Wiring formStar low-voltage to RCU hostGateway + wireless panels/modules, minimal cabling
Construction windowNew build / full fit-out with structureExisting retrofit, short schedule, minimal wall opening
Scene response★★★★★ local relays, low latency★★★★☆ gateway and battery maintenance
Circuit expansionRelay/dimmer modules as neededLimited by wireless points and gateway capacity
TroubleshootingTerminal table + wire numbers, electrician-friendlyGateway logs + module pairing
Typical projectLuxury new build, full-fit business hotelLegacy retrofit, B&B economy
PurePoint Smart docsThis page wiring table ·wiring atlasWireless tech solution →

Wired hardware topology · Layer guide

Wired RCU single-room star wiring topology board

Star network structure

Panels, card power, door sensors, thermostatsstar home-runto RCU host — per-room isolated, no cross-room chaining; relay modules drive mains circuits centrally.

  • RCU in LV riser / wardrobe access panel
  • Scene logic on host locally; offline persistence
  • Optional integrator gateway to PMS
Wired host models →

Single-room star wiring table

Core referencefor wired guestroom control — tender docs, LV drawings, and acceptance lists use this structure; wire numbers, conduit size, and RCU terminals in project wiring atlas.

PointCable typeRCU connectionNotes
Door sensor · doorbellRVV 2×0.75 mm²DI-01 / DI-02Normally-closed door sensor; doorbell dry contact shares LV riser withdoor sign DND/MUR
Entry triple · card powerRVV 4×0.75 mm²RELAY-01 + DI-03Card power contacts control main/sub circuits; seecard power logic
ThermostatRVSP 2×0.75 mm² (shielded pair)RS485-A/B or HVAC moduleFCU / VRF; Welcome / vacant perHVAC solution
Left · right bedsideRVV 6×0.75 mm²PANEL-BUS L / RBright / sleep / read; curtains linkmotorized shading
Desk triple panelRVV 4×0.75 mm²PANEL-BUS-03Desk lamp, outlets, USB; same key map asinfo panel
RCU smart hostRVV 3×1.5 mm² + star hubLV riser / wardrobe accessLocal scene persistence; open protocol ·model catalog

* Wire gauge, cores, and terminal IDs per signed wiring atlas; chain projects lock BOM revision for cross-store copy.

Construction and acceptance checklist

Conduit and wire labels

Star LV in dedicated conduit, not shared with mains; label every terminal per wiring atlas revision.

RCU enclosure

LV riser access and cooling; host power RVV 3×1.5 dedicated circuit, not shared with outlets.

Full scene chain

Test Welcome, card-out delay, DND door sign 3× each; attach toenergy-savingacceptance pack.

Per-room sign-off

Terminal table + circuit checklist; chain new stores clone specified BOM revision, no on-site wire number changes.

Recommended models

Guestroom control technology · Four deployment routes

Wired guestroom control is route A; RS485 bus and modular chassis can combine on same property type.

→ Parent four-route tab comparison·Engineering solutions index

Related in-room capability solutions (9 items)

After wired topology is set, deepen logic and models per subsystem — common engineering entry points below.