RCU Controllers

128-ch RS485 RCU host

128-ch RS485 RCU host — 128-circuit RS485 bus for integrator bulk rollout. RS485/Modbus RTU or wireless Mesh; manages switch panels and guestroom scenes.

128-ch RS485 RCU host

128-ch RS485 RCU host — 128-circuit RS485 bus for integrator bulk rollout. RS485/Modbus RTU or wireless Mesh; manages switch panels and guestroom scenes.

  • 128-circuit
  • RS485
  • Expansion
  • 128-circuit capacity selection
  • new-build hotel centralized cabling
  • multi-property chain replication
  • high-circuit-count guest rooms and public areas
RS485 RCU guestroom control host centralized management of guestroom and public-area circuits
RS485 bus to terminal modules/panels
Topology star / bus · addresses plannable
Protocol Modbus RTU · BMS integration
Application upscale hotels · chains · high circuit count
Circuit capacity
128-ch RS485 RCU host
Bus
RS485
Capacity
pertype No. 80~
Topology
star / bus · addresses plannable
Protocol
Modbus RTU · BMS integration

Specifications

Parameter Specification
Product name 128-ch RS485 RCU host
Product series RS485 busguestroom control host
Circuit capacity RS485 RCU guestroom control host
Bus 128-ch RS485 RCU host — 128-circuit RS485 bus for integrator bulk rollout. RS485/Modbus RTU or wireless Mesh; manages switch panels and guestroom scenes.
Topology star / bus · addresses plannable
Capacity pertype No. 80~
Protocol Modbus RTU · BMS integration
Communication protocol Modbus RTU · BMS integration
Installation low-voltage cabinet / equipment room / DIN rail(model-dependent)
Delivery bulk project supply · detailed designschedule with construction drawingssync

Wiring diagram

RS485 bus RCU host engineering wiring reference — bus cascading, terminal addressing, and BMS integration; refer to signed drawing set for terminal details.

RS485 busguestroom control host wiring diagram
in-room bus → RCU host → guestroom terminal actuation

Installation notes

  • Bus address schedule must be planned with the circuit schedule during detailed design to avoid conflicts
  • Long-distance buses require termination resistors and shield grounding per specification
  • Wire per project drawing; signed projects use factory shipment drawings
  • After power-on, commission with each slave station: Modbus communication and scene logic, item-by-item acceptance

Companion hotel smart switch panels

RCU hosts coordinate guestroom loads with smart switch and scene panels on RS485 or wireless bus.

requiresRS485 busguestroom control hostselection andbusplanning? Contact our team for address schedule templates, bus topology, and chain replication solutions.